DigiBooster

42 000 Ft

available

Main parameters:

  • To amplify a NMRA DCC compliant rail signal,
  • From 2A to 8A adjustable output load capacity,
  • compatible with all NMRA DCC compliant control panels:
    • Roco z21, Z21, multiMAUS,
    • LENZ,
    • ESU,
    • FREMO,
    • etc.
  • communication according to NMRA DCC standards,
  • the output is protected against short-circuit current,
  • useful features:
    • automatic polarity reversal,
    • automatic reconnection,
    • own temperature monitoring, 3-step protection level against overheating,
  • using the DigiMonitor program for chacking the status of the Booster (s) via PC
    •  the below can be observed:
      • operating condition,
      • temperature,
      • power consumption,
    • can be modified:
      • amplifier(s) can be switched on and off individually and in groups,
      • can be approved and reconnected after a short circuit,
  • Requirements for the power supply connected to the Booster:
    • can only be used from stabilized DC power supply, input voltage DC 14V – 24V
    • its power must be at least 1.2 times of the current that is set on the short-circuit amplifier!
For more information, see the device decoder user manual (in the "Downloads" folder) in the following topics.
  • general description,
  • main parameters,
  • device explanation:
    • internal parts,
    • front panel interfaces, LED and push button,
    • back panel interfaces, LED and push button,
  • setting amplifier:
    • connecting power supply,
    • connecting DCC output,
    • some important basic rules for connecting amplifiers:
      • control connection,
      • By connecting Roco multiMAUS as Master,
      • Connecting XPressNet "Slave" devices,
      • by connecting the outputs of the LENZ LZV200 CDE,
      • using an amplifier bus connection,
      • FREMO DCC signal connection,
      • providing a control signal via the DigiMonitor bus,
      • Direct connection of DCC signal,
  • parameter setting:
    • amplifier parameters,
    • short-circuit current value,
    • reversing polarity automatically,
    • selection of reconnection modes,
    • number of automatic reconnection attempts,
    • the time elapsed between automatic reconnection attempts,
    • resetting to default values,
    • first temperature alarm level,
    • second temperature alarm level,
    • third temperature alarm level,
    • first switch-on delay,
    • Enabling Buzzer
  • operating conditions, feedback:
    • "Normal" operating condition
    • "Fault" operating condition (due to short circuit or overheating),
    • Operating status after "switch-on",
    • "Stop" operating state,
  • communication with DigiMonitor PC monitoring software,
  • CVs - summary table,
  • Status Indicators - Summary.
preloader